50119927-5 October 2016
Thermo Scientific
Sorvall Legend XTSorvall Legend XTR
Instruction manual
© 2011 Thermo Fisher Scientific Inc. All rights reserved.
BIOLinerTM, BIOShieldTM, HIGHPlateTM, HIGHConicTM, AutoLockTM and FIBERLite TM are either registered trademarks or trademarks of Thermo Fisher Scientific.
All other trademarks are the property of Thermo Fisher Scientific Inc. and its subsidiaries.
Thermo Fisher Scientific Inc. provides this document to its customers with a product purchase to use in the product operation. This document is copyright protected and any reproduction of the whole or any part of this document is strictly prohibited, except with the written authorization of Thermo Fisher Scientific Inc.
The contents of this document are subject to change without notice. All technical information in this document is for reference purposes only. System configurations and specifications in this document supersede all previous information received by the purchaser.
Thermo Fisher Scientific Inc. makes no representations that this document is complete, accurate or errorfree and assumes no responsibility and will not be liable for any errors, omissions, damage or loss that might result from any use of this document, even if the information in the document is followed properly.
This document is not part of any sales contract between Thermo Fisher Scientific Inc. and a purchaser. This document shall in no way govern or modify any Terms and Conditions of Sale, which Terms and Conditions of Sale shall govern all conflicting information between the two documents.
Original instruction manual 50119927-5 printed in October 2016.
Thermo Electron LED GmbH Zweigniederlassung Osterode Am Kalkberg37520 Osterode am Harz Germany
WEEE Conformity
This product is subject to the regulations of the EU Waste Electrical & Electronic Equipment (WEEE) Directive 2002/96. It is marked by the following symbol:
Thermo Fisher Scientific has entered into agreements with recycling and disposal companies in all EU Member States for the recycling and disposal of this device. For information on recycling and disposal companies in Germany and on the products of Thermo Fisher Scientific, which fall under the RoHS Directive (Restriction of the use of certain hazardous substances in electrical and electronic equipment), please visit the website www.thermo.com/WEEERoHS
Thermo Scientific Sorvall Legend XT i
T
Preface .......................................................................................................................................iii
Scope of Supply ........................................................................................................................iii
Intended Use .............................................................................................................................iii
Accident Prevention ................................................................................................................ iv
Precautions ............................................................................................................................... iv
Chapter 1 Introduction and Description ...............................................................................................1-1Characteristics of the Sorvall Legend XT/XTR ........................................................1-2Technical Data .........................................................................................................1-3Directives, Standards and Guidelines ............................................................................1-4Functions and Features .............................................................................................................1-5Mains Supply ...........................................................................................................1-5Rotor Selection .........................................................................................................1-6
Chapter 2 Before use ................................................................................................................................2-1Before Setting up ......................................................................................................2-2Transporting the Centrifuge .....................................................................................2-2Location ...................................................................................................................2-2Aligning the Centrifuge ............................................................................................2-3Mains Connection ....................................................................................................2-3Storage .....................................................................................................................2-4
Chapter 3 Control Panel ...........................................................................................................................3-1Control Panel ...........................................................................................................3-2Keys .........................................................................................................................3-2
Chapter 4 Operation .................................................................................................................................4-1Switch on Centrifuge ................................................................................................4-2Lid Opening .............................................................................................................4-2Close Lid ..................................................................................................................4-2Rotor Installation .....................................................................................................4-2Entering Parameters .................................................................................................4-4Centrifugation ........................................................................................................4-10Temperature Adaptation during Standstill ..............................................................4-11Short-term Centrifugation ......................................................................................4-11Removing the Rotor ...............................................................................................4-11Aerosol-tight Rotors ...............................................................................................4-12Aligning the Centrifuge ..........................................................................................4-12
Table of Contents
Contents
ii Sorvall Legend XT Thermo Scientific
Chapter 5 System Menu .......................................................................................................................... 5-1Description .............................................................................................................. 5-2
Chapter 6 Maintenance and Care ......................................................................................................... 6-1Cleaning Intervalls ................................................................................................... 6-2Cleaning .................................................................................................................. 6-2Disinfection ............................................................................................................. 6-3Decontamination ..................................................................................................... 6-4Autoclaving .............................................................................................................. 6-5Service of Thermo Fisher Scientific .......................................................................... 6-5
Chapter 7 Trouble Shooting .................................................................................................................... 7-1Mechanical Emergency Door Release ...................................................................... 7-2Troubleshooting by User ......................................................................................... 7-3When to contact Customer Service .......................................................................... 7-5
Chemical Compatibility Chart ...............................................................................A-1
Contact Information ................................................................................................B-1
Thermo Scientific Sorvall Legend XT iii
P
Preface
Before starting to use the centrifuge, read through this instruction manual carefully and follow the instructions.
The information contained in this instruction manual is the property of Thermo Fisher Scientific; it is forbidden to copy or pass on this information without explicit approval.
Failure to follow the instructions and safety information in this instruction manual will result in the expiration of the sellers warranty.
Scope of Supply
If any parts are missing, please contact your nearest Thermo Fisher Scientific representative.
Intended Use
• This centrifuge is an IVD accessory, and therefore subject to the Directive 98/79/EC of the European Parliament and the Council of October 27, 1998 on in vitro diagnostic medical devices.
• This centrifuge is a laboratory product designed to separate components by generation of Relative Centrifugal Force. It separates human samples (e.g. blood, urine and other body fluids) collected in appropriate containers, either alone or after addition of reagents or other additives.
• As general-purpose centrifuge, it is designed to also run other containers filled with chemicals, environmental samples and other non-human body samples.
• This centrifuge should be operated by trained specialists only.
Article Number Quantity Check
Centrifuge Sorvall Legend XT 1
Power supply cable 1
50119927 Instruction manual 1
70009824 Anti-corrosion oil 1
P Accident Prevention
iv Sorvall Legend XT Thermo Scientific
Accident Prevention
Prerequisite for the safe operation of the Sorvall Legend XT/XTR is a work environment in compliance with standards, directives and trade association safety regulations and proper instruction of the user.
The safety regulations contain the following basic recommendations:
• Maintain a radius of at least 30 cm around the centrifuge.
• Implementation of special measures which ensure that no one can approach the centrifuge forlonger than absolutely necessary while it is running.
• The mains plug must be freely accessible at all times. Pull out the power supply plug ordisconnect the power supply in an emergency.
Precautions
In order to ensure safe operation of the Sorvall Legend XT/XTR, the following general safety regulations must be followed:
• The centrifuge should be operated by trained specialists only.
• The centrifuge is to be used for its intended use only.
• Plug the centrifuge only into sockets which have been properly grounded.
• Do not move the centrifuge while it is running.
• Do not lean on the centrifuge.
• Use only rotors and accessories for this centrifuge which have been approved by Thermo FisherScientific. Exceptions to this rule are commercially available glass or plastic centrifuge tubes,provided they have been approved for the speed or the RCF value of the rotor.
• Do not use rotors which show any signs of corrosion and/or cracks.
• Do not touch the mechanical components of the rotor and do not make any changes to themechanical components.
• Use only with rotors which have been properly installed. Follow the instructions on the Autolockin section “Rotor Installation” on page 4-2.
• Use only with rotors which have been loaded properly. Follow the instructions given in the rotormanual.
• Never overload the rotor. Follow the instructions given in the rotor manual.
• Never start the centrifuge when the lid is open.
• Never open the lid until the rotor has come to a complete stop and this has been confirmed inthe display.
P Precautions
Thermo Scientific Sorvall Legend XT v
• The lid emergency release may be used in emergencies only to recover the samples from the centrifuge, e.g. during a power failure (see section “Mechanical Emergency Door Release” on page 7-2).
• Never use the centrifuge if parts of its cover panels are damaged or missing.
• Do not touch the electronic components of the centrifuge or alter any electronic or mechanical components.
• Please observe the safety instructions.
Please pay particular attention to the following aspects:
• Location: well-ventilated environment, set-up on a level and rigid surface with adequate load-bearing capacity.
• Rotor installation: make sure the rotor is locked properly into place before operating the centrifuge.
• Especially when working with corrosive samples (salt solutions, acids, bases), the accessory parts and vessel have to be cleaned carefully.
• Always balance the samples.
Centrifuging hazardous substances:
• Do not centrifuge explosive or flammable materials or substances which could react violently with one another.
• The centrifuge is neither inert nor protected against explosion. Never use the centrifuge in an explosion-prone environment.
• Do not centrifuge inflammable substances.
• Do not centrifuge toxic or radioactive materials or any pathogenic micro-organisms without suitable safety precautions.
When centrifuging microbiological samples from the Risk Group II (according to the Bio-safety Manual" of the World Health Organization WHO), aerosol-tight biological seals have to be used.
For materials in a higher risk group, extra safety measures have to be taken.
• If toxins or pathogenic substances have gotten into the centrifuge or its parts, appropriate disinfection measures have to be taken (see “Disinfection” on page 6-3).
• Highly corrosive substances which can cause material damage and impair the mechanical stability of the rotor, should only be centrifuged in corresponding protective tubes.
IF A HAZARDOUS SITUATION OCCURS, TURN OFF THE POWER SUPPLY TO THE CENTRIFUGE AND LEAVE THE AREA IMMEDIATELY.
Intended Use
The centrifuge is to be used for separating materials of different density or particle size suspended in a liquid.
Maximum sample density at maximum speed: 1,2 gcm3-----------
P Precautions
vi Sorvall Legend XT Thermo Scientific
This symbol refers to general hazards.
CAUTION means that material damage could occur.
WARNING means that injuries or material damage or contamination could occur.
This symbol refers to biological hazards.
Observe the information contained in the instruction manual to keep yourself and your environment safe.
Thermo Scientific Sorvall Legend XT 1-1
1
Introduction and Description
Contents
• “Characteristics of the Sorvall Legend XT/XTR” on page 1-2
• “Technical Data” on page 1-3
• “Directives, Standards and Guidelines” on page 1-4
• “Functions and Features” on page 1-5
• “Mains Supply” on page 1-5
• “Rotor Selection” on page 1-6
1 Introduction and DescriptionCharacteristics of the Sorvall Legend XT/XTR
1-2 Sorvall Legend XT Thermo Scientific
Characteristics of the Sorvall Legend XT/XTRThe Sorvall Legend XT/XTR is an in-vitro diagnostics device according to the In-Vitro Diagnostics Directive 98/79/EC.
Several rotors with a wide range of tubes can be used.
The set speed is reached within seconds. The maintenance-free induction motor ensures quiet and low-vibration operation even at high speeds, and guarantees a very long lifetime.
The user-friendly control panel makes it easy to pre-set the speed, RCF value, running time, temperature, and running profile (acceleration and braking curves). You can choose between the display of speed and RCF or the entry mode.
These settings can be changed even while the centrifuge is running.
With the help of the PULSE key , you can also centrifuge a sample for just a few seconds, if called for.
The Sorvall Legend XT/XTR is equipped with various safety features:
• The housing and rotor chamber consist of steel plate, the interior of armour steel, while the front panel is made of high-impact resistant plastic.
• The lid is equipped with a view port and a lock.
• The lid of the centrifuge can only be opened while the centrifuge is switched on and the rotor has come to a complete stop. The centrifuge cannot be started until the lid has been closed properly.
• The integrated rotor detection systems ensures that no inadmissible speed settings can be preselected.
• Electronic imbalance recognition
• Lid emergency release: For emergencies only, e.g. during power failures (see “Mechanische Notentriegelung des Deckels” auf Seite 7-2)
1 Introduction and DescriptionTechnical Data
Thermo Scientific Sorvall Legend XT 1-3
Technical DataThe technical data of the Sorvall Legend XT/XTR is listed in the following table.
Table 1-1. Technical Data Sorvall Legend XT/XTR
Feature Value
Environmental conditions -Use in interior spaces
-Altitudes of up to 2,000 m above sea level
-max. relative humidity 80% up to 31 °C; decreasing linearly up to 50% relative humidity at 40 °C.
permissible ambient temperature +2 °C to +35 °C +2 °C to +35 °C
Overvoltage category II II
Pollution degree 2 2
Heat dissipation ventilated refrigerated
230V 120V 230V 120V
5800 BTU/h 4776 BTU/h 6653 BTU/h 4776 BTU/h
IP 20 20
running time unlimited unlimited
max Speed nmax 15200 rpm (depending on the rotor) 15200 rpm (depending on the rotor)
min Speed nmin 300 rpm 300 rpm
maximum RCF value at nmax 25314 x g 25314 x g
maximum kinetic energy < 62.5 kJ < 62.5 kJ
noise level at maximum speed < 64 dB (A) < 64 dB (A)
temperature setting range -10 °C to +40 °C
Dimensions ventilated refrigerated
HeightWidthDepthTable top height
360 mm 550 mm 670 mm 310 mm
360 mm 745 mm 670 mm 310 mm
weight without rotor 86 kg 116 kg
1 Introduction and DescriptionDirectives, Standards and Guidelines
1-4 Sorvall Legend XT Thermo Scientific
Directives, Standards and GuidelinesTable 1-2. Directives, Standards and Guidelines
Tension / Frequency
Produced and inspected according to the following standards and guidelines
230V 50/60Hz 2006/95/EC Low Voltage Directive:
2006/42/EC & 98/37/EC Machine Directive:
2004/108/EC EMC Directive
98/79/EC In-vitro-Diagnostika (IvD)
EN 61010-1, 2nd Edition
EN 61010-2-020, 2nd Edition
EN 61010-2-101
EN 61326-1
EN 61326-2-6
EN 55011B
EN 61000-6-2
EN ISO 13485
230V 60Hz
120V 60Hz
100V 60Hz
UL 61010-1, 2nd Edition
CAN/CSA-C22.2 No. 61010-1, 2nd Edition
IEC 61010-2-20, 2nd Edition
(Pollution degree 2, Overvoltage category II)
IEC 61010-2-101
Emitted interference FCC Part 15 CLASS A
NOTE: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense.
100V 50Hz IEC 61010-1 2nd Edition
IEC 61010-2-020 2nd Edition
IEC 61010-2-101
EN 61326-1
EN 61326-2-6
EN 55011A
EN 61000-6-2
EN ISO 13485
1 Introduction and DescriptionFunctions and Features
Thermo Scientific Sorvall Legend XT 1-5
Functions and FeaturesThe following table gives an overview of the important functional and performance characteristics of the Sorvall Legend XT/XTR.
Mains SupplyThe following table contains an overview of the electrical connection data for the Sorvall Legend XT/XTR. This data is to be taken into consideration when selecting the mains connection socket.
Table 1-3. Functions and Features
Component / Function Description / Features
Structure / Housing Galvanized steel chassis with armoured plating
Chamber Stainless steel / varnished steel
Drive Induction drive without carbon brushes
Keys and display Easy-to-clean keypad and display surface
Controls Microprocessor-controlled
Internal memory The most recent data is saved
Functions RCF-selection, temperature control, pretemp with cooling equipped devices
Acceleration / braking profiles 9 acceleration and 10 braking curves
Rotor recognition Automatic
Imbalance recognition Electronic, contingent on rotor and speed
Lid lock Automatic lid closing and locking starting from an initial hold position
Table 1-4. Electrical connection data of the Sorvall Legend XT/XTR
Cat. Mains voltage Frequency Rated
currentPower consumption
Equipment fuse
Building fuse
7500 4520 refrigerated 230 V 50 / 60 Hz 10.5 A 1950 W 15 AT 16 AT
7500 4521 refrigerated 120 V 60 Hz 12 A 1400 W 15 AT 15 AT
7500 4522 refrigerated 100 V 50 / 60 Hz1
1 Please contact an authorized customer service representative for running the centrifuge at 60Hz.
10.5 A 1950 W 15 AT 16 AT
7500 4523 refrigerated 230 V 60 Hz 10.5 A 1850 W 15 AT 15 AT
7500 4505 ventilated 230 V 50 / 60 Hz 11 A 1700 W 15 AT 16 AT
7500 4506 ventilated 120 V 60 Hz 12 A 1400 W 15 AT 15 AT
7500 4507 ventilated 100 V 50 / 60 Hz 10.5 A 1950 W 15 AT 16 AT
7500 4508 ventilated 230 V 60 Hz 10.5 A 1950 W 15 AT 15 AT
1 Introduction and DescriptionRotor Selection
1-6 Sorvall Legend XT Thermo Scientific
Rotor Selection The Sorvall Legend XT/XTR is supplied without a rotor.
Various rotors are available to choose from.
The technical data of the rotors and the corresponding adapters and reduction sleeves for various commercially available containers can be found in the corresponding rotor operating manuals.
For more information visit our website at: http://www.thermo.com
TX-750 7500 3607
with round buckets 7500 3608
with rectangular buckets 7500 3614
incl. Microtiter carrier 7500 3617
incl. ABI-bucket 7500 3618
BIOshieldTM 1000A 7500 3603
BIOLinerTM 7500 3667
HIGHPlateTM 6000 7500 3606
FIBERLiteTM H3LV 7500 3665
FIBERLiteTM F14S-6 x 250 LE 7500 3662
FIBERLiteTM F15-6 x 100 7500 3698
FIBERLiteTM F13S-14 x 50c 7500 3661
FIBERLiteTM F15-8 x 50c 7500 3663
FIBERLiteTM F21-48 x 2 7500 3664
Microliter 48 x 2 7500 3602
HIGHConicTM 6 x 100 7500 3620
M-20 7500 3624
Thermo Scientific Sorvall Legend XT 2-1
2
Before use
Contents
• “Before Setting up” on page 2-2
• “Transporting the Centrifuge” on page 2-2
• “Location” on page 2-2
• “Aligning the Centrifuge” on page 2-3
• “Mains Connection” on page 2-3
• “Storage” on page 2-4
2 Before useBefore Setting up
2-2 Sorvall Legend XT Thermo Scientific
Before Setting up1. Check the centrifuge and the packaging for any shipping damage.
Inform the shipping company and Thermo Fisher Scientific immediately if any damage is discovered.
2. Remove the packaging.
3. Check the order for completeness (see “Scope of Supply” on page iii).If the order is incomplete, please contact Thermo Fisher Scientific.
Transporting the Centrifuge• Due to its weight (see “Technical Data” on page 1-3), the centrifuge should be carried by several
people.
• Always lift the centrifuge at both sides.
Figure 2-1. Lifting the centrifuge at both sides.
• The centrifuge can be damaged by impacts.
• Transport the centrifuge upright and if at all possible in its packaging.
LocationThe centrifuge should only be operated indoors.
The set-up location must fulfil the following requirements:
• A safety zone of at least 30 cm must be maintained around the centrifuge.People and hazardous substances must be kept out of the safety zone while centrifuging.
• The supporting structure must be stable and free of resonance, for example a level laboratory bench.
• The supporting structure must be suitable for horizontal setup of the centrifuge.
WARNING Always lift the centrifuge on both sides. Never lift the centrifuge by its front or the back panel.Always remove the rotor before moving the centrifuge.
2 Before useAligning the Centrifuge
Thermo Scientific Sorvall Legend XT 2-3
• The centrifuge should not be exposed to heat and strong sunlight.
• The set-up location must be well-ventilated at all times.
Aligning the CentrifugeThe horizontal alignment of the centrifuge must be checked every time after moving it to a different location. The supporting structure must be suitable for horizontal setup of the centrifuge.
Mains Connection
Figure 2-2. Mains Connection
1. Turn off the power supply switch on the back (press "0").
2. Plug the centrifuge into grounded electrical sockets only.
3. Check whether the cable complies with the safety standards of your country.
4. Make sure that the voltage and frequency correspond to the figures on the rating plate.
5. Establish the connection to the power supply with the connecting cable.
WARNING UV rays reduce the stability of plastics.Do not subject the centrifuge, rotors and plastic accessories to direct sunlight.
CAUTION If the centrifuge isn’t level, imbalances can occur and the centrifuge can be damaged.Do not place anything under the feet to level the centrifuge.
Main Power Switch
Mains plug
2 Before useStorage
2-4 Sorvall Legend XT Thermo Scientific
Storage• Before storing the centrifuge and the accesories it must be cleanedand if necessary desinfected and
decontaminated.
• Store the centrifuge in a clean, dust-free location.
• Be sure to place the centrifuge on its feet.
• Avoid direct sunlight.
Thermo Scientific Sorvall Legend XT 3-1
3
Control Panel
Contents
• “Control Panel” on page 3-2
• “Keys” on page 3-2
3 Control PanelControl Panel
3-2 Sorvall Legend XT Thermo Scientific
Control PanelThe control panel contains the keys and displays of the centrifuge (only the power switch is located on the back of the device). All parameters can be selected and changed during operation.
Keys The keys allow user intervention for controlling the operating mode as follows:
PULSEProgram selection keys
OPENDisplay
Directory keySPEED STARTTIME ENTER
Braking and Acceleration Key
TEMP
Changing the display mode Speed / RCF Value
numeric pad
BucketSTOP
Changing the display mode Running time / Remaining Running time
Changing the display mode chamber / sample temperature
Key Display contents
StartNormal start of the centrifuge
StopEnd run manually
Open lidAutomatic release (possible only when device is switched on). Emergency release (see “Mechanical Emergency Door Release” on page 7-2)
PulseBy pressing the key PULSE the centrifuge starts immediately and accelerates up to the end speed. Releasing the key initiates a stopping process at the highest braking curves.
DirectoryUse the directory key in order to modify the displayed value
BucketUse the bucket key in order to have all available bucket types displayed in succession.
Braking and Acceleration Curves
Use the ACC DEC key to toggle between braking and acceleration curves.
Changing the display mode
Use the Toggle key to change the display mode. (speed / RCF value, sample / chamber temperature, run time counter from start or preset speed on)
Thermo Scientific Sorvall Legend XT 4-1
4
Operation
Contents
• “Switch on Centrifuge” on page 4-2
• “Lid Opening” on page 4-2
• “Rotor Installation” on page 4-2
• “Entering Parameters” on page 4-4
• “Centrifugation” on page 4-10
• “Temperature Adaptation during Standstill” on page 4-11
• “Short-term Centrifugation” on page 4-11
• “Removing the Rotor” on page 4-11
• “Aligning the Centrifuge” on page 4-12
4 OperationSwitch on Centrifuge
4-2 Sorvall Legend XT Thermo Scientific
Switch on Centrifuge1. Turn on the power switch on the back of the device.
The device performs a self-check of its software.
a. When the centrifuge lid is closed the following display shows:
The top line shows the speed and the time. Both lines display 0. The temperature indicator displays the current temperature inside the rotor chamber. The bottom line shows the values for the last run.
b. When the centrifuge lid is open the following display shows:
The top line shows the message "Lid open". The bottom line shows the values for the last run.
Lid Opening 1. Press the OPEN key .
Close Lid2. Close the lid by pressing down on it lightly in the middle or on both sides of it. Two locks close the
lid completely.
Rotor InstallationThe approved rotors for the Sorvall Legend XT/XTR are listed in section “Rotor Selection” on page 1-6. Use only the rotors and accessories from this list in the centrifuge.
WARNING Do not reach into the crack between the lid and the housing. The lid is drawn shut automatically.
Use the emergency release only for malfunctions and power failures (see “Mechanical Emergency Door Release” on page 7-2).
Note The lid should audibly click into place.
4 OperationRotor Installation
Thermo Scientific Sorvall Legend XT 4-3
The centrifuge is equipped with an AutoLockTM locking system.This system is used to automatically lock the rotor to the centrifuge spindle. The rotor does not have to be bolted on to the centrifuge spindle.
Proceed as follows:
1. Open the lid of the centrifuge and if necessary remove any dust, foreign objects or residue from the chamber. AutoLockTM and o-ring must be clean and undamaged.
Figure 4-1. AutoLockTM
2. Place the rotor over the centrifuge spindle and let it slide slowly down the centrifuge spindle.The rotor clicks automatically into place.
3. Check if the rotor is properly installed by lifting it slightly on the handle. If the rotor can be pulled up, then it must be reclamped to the centrifuge spindle.
CAUTION Unapproved or incorrectly combined accessories can cause serious damage to the centrifuge.
CAUTION Do not force the rotor onto the centrifuge spindle.If the rotor is very light, then it may be necessary to press it onto the centrifuge spindle with a bit of pressure.
WARNING If the rotor cannot be properly locked in place after several attempts, then the AutoLockTM is defective and you are not permitted to operate the rotor.Check for any damage to the rotor: Damaged rotors must not be used.Keep the centrifuge spindle area of the rotor clear of objects.
CAUTION Check that the rotor is properly locked on the centrifuge spindle before each use by pulling it at its handle.
AutoLockTM
O-Ring
4 OperationEntering Parameters
4-4 Sorvall Legend XT Thermo Scientific
4. If available close the rotor with the rotor lid.
5. The display shows:
Entering Parameters
Acceleration curve
The Sorvall Legend XT/XTR offers you a total of 9 acceleration and 10 braking curves with which samples and gradients can be centrifuged.
After the centrifuge is turned on, the last running profile selected is shown.
1. Press the ACC DEC key once in order to open the acceleration profile selection menu. The display shows the message "Set acceleration".
2. Select the desired profile by entering a digit between 1-9 on the numeric pad. Curve number 1 is the slowest and curve number 9 the fastest.
3. Confirm your entry by pressing ENTER .
Braking curve
1. Press the ACC DEC key twice in order to open the braking curve selection menu. The display shows the message "Set deceleration“
2. Select the desired curve by entering a digit between 1-9 on the numeric pad. Curve number 1 is the slowest and curve number 10 the fastest.
3. Confirm your entry by pressing ENTER .
Preselecting Speed / RCF
1. Press the SPEED key .The display shows the "RPM“ or the "RCF"-value depending on the display setting. Press the
Be sure to check all sealings before starting any aeorsol-tight applications.
See the information in the rotor instruction manual.
4 OperationEntering Parameters
Thermo Scientific Sorvall Legend XT 4-5
TOGGLE key to toggle between the two modes.
2. Enter the desired value using the numeric pad. The digits show in sequential order.
3. Confirm your entry by pressing ENTER .Your entry will be automatically confirmed if you do not press any key for 5 seconds.
Running time preselection
1. Press the TIME key in order to open the runtime selection menu. The display shows the message "Set Time".Enter the desired runtime in hh.mm
Note If an extremely low RCF value has been selected, it will be corrected automatically if the resulting speed is less than 300 rpm. This is because 300 rpm is the lowest selectable speed.
Explanation of RCF Value
The relative centrifugal force is given as a multiple of the force of gravity g. It is a unitless numerical value which is used to compare the separation or sedimentation capacity of various devices, since it is independent of the type of device. Only the centrifuging radius and the speed come into play in it:
r = centrifuging radius in cm
n = Rotational speed in rpm
The maximum RCF value is related to the maximum radius of the tube opening.
Remember that this value is reduced depending on the tubes and adapters used.
This can be accounted for in the calculation above if required.
RCF 11 18, n1000-------------⟨ ⟩
2r××=
4 OperationEntering Parameters
4-6 Sorvall Legend XT Thermo Scientific
2. Press the TIME key repeatedly to switch over to mm:ss or Hold mode respectively.
3. Enter the desired runtime using the numeric pad. The digits show in sequential order.
4. Confirm your entry by pressing ENTER .Your entry will be automatically confirmed if you do not press any key for 5 seconds.
While the centrifuge is in operation, two different values can be displayed. The total running time and the running time after reaching the maximum speed. Press the CHANGE key to toggle between the two display modes.
Continuous operation
During continuous operation, the centrifuge will continue running until you stop it manually with the STOP key .
Run time mode
Use the TOGGLE key to set the run time counter start.
AT START
When AT START is lit, the running time will be counted right from pressing the START key .
AT SPEED
When AT SPEED is lit, the running time will be counted once the preset speed or the preset RCF-value respectively have been reached. In this case, the selected acceleration curve has no effect on the running time.
Preselecting the temperature
You can preselect temperatures between -10 °C and +40 °C.
While the centrifuge is in operation, two different values can be displayed. The sample temperature and the chamber temperature. Press the TOGGLE key to toggle between the two display modes.
AIR
When AIR is lit, the temperature inside the rotor chamber will be controlled. This setting is recommended when using the centrifuges pretemp feature.
4 OperationEntering Parameters
Thermo Scientific Sorvall Legend XT 4-7
SAMPLE
When SAMPLE is lit, the temperature of the sample will be controlled.
To set the temperature, proceed as follows:
1. Press the TEMPERATURE key in order to open the temperature selection menu. The display shows the messages "Temperature". Depending on the display mode setting, the value shown corresponds either to the sample temperature or to the inside chamber temperature. Press the TOGGLE key to toggle between the two modes.
2. Enter the desired temperature using the numeric pad. The digits show in sequential order.
3. Confirm your entry by pressing ENTER .Your entry will be automatically confirmed if you do not press any key for 5 seconds.
Prewarming or precooling the centrifuge
For setting the pretemp value for the centrifuge proceed as follows:
1. Hold down the TEMPERATURE key for a minimum of three seconds to open the temperature selection menu. The display shows the message "Set PreTemp".
2. Enter the desired temperature using the numeric pad. The digits show in sequential order.
3. Confirm your entry by pressing ENTER .Your entry will be automatically confirmed if you do not press any key for 5 seconds.
4. The display shows:The display shows:
4 OperationEntering Parameters
4-8 Sorvall Legend XT Thermo Scientific
5. Press the START key . The rotor chamber is cooled down or heated up to the preset temperature.
6. Press the STOP key .The display shows the current temperature.
Bucket selection
Bucket selection is only possible for swing-out rotors.The bucket code corresponds to the last four digits of the bucket catalog number.
1. Press the BUCKET key .The display shows the following message:
2. Press the BUCKET key repeatedly until the bucket being used is displayed.Your entry will be automatically confirmed if you do not press any key for 5 seconds.
Bucket radius
Having entered the bucket code, you may want to specify the radius.
When you use adaptors, you will have to specify the radius. For appropriate values please refer to the instruction manual for the rotor.
1. Press ENTER to confirm your selection and open the radius input menu.
4 OperationEntering Parameters
Thermo Scientific Sorvall Legend XT 4-9
The default value is marked accordingly. You can either confirm the default value by pressing ENTER or enter a different radius.
2. Enter the radius using the numeric pad. The digits show in sequential order.
3. Press ENTER to confirm the new radius.
Setting up a program
Enter the program parameters.
As described above, please enter braking and acceleration profile, speed/ RCF value, running time, temperatures, bucket code and bucket radius.
Configuring, storing and protecting a program
Programs can be stored and retrieved later by means of the assigned number.
1. Enter the program parameters as described above.
2. Press the program memory key to load any of the programs 1-5. Press the DIRECTORY key in order to load any of the programs 1-99 by means of the numeric pad.Enter the program number and confirm with ENTER key .
3. You may want to enter a passcode to protect the data. After four seconds the display shows the message "Program saved" or "Program locked".
Overwriting a passcode-protected program
If you wish to overwrite a passcode-protected program proceed as follows:
1. Select the program you wish to change.
2. Press the program memory key to load any of the programs 1-5. Press the DIRECTORY key in order to load any of the programs 1-99 by means of the numeric pad.
4 OperationCentrifugation
4-10 Sorvall Legend XT Thermo Scientific
Enter the program number and confirm with ENTER key .
3. Enter the passcode.If you enter the wrong password, the following message appears:
The display restores the current values. Return to step 1.
CentrifugationOnce the rotor has been properly installed, the main switch has been turned on and the lid has been closed, you can start centrifuging.
Starting centrifuge program
Press the START key on the control panel. The centrifuge accelerates to the pre-set speed with the time display active.
If the speed setting is higher than the maximum permissible speed or RCF-value for the particular rotor, then the display will show the message CHECK SET SPEED. The centrifuge decelerates. Please enter a new value.
You cannot open the lid as long as the centrifuge is running.
Imbalance indicator
If a load is imbalanced, this will be indicated at speed higher than approx. 300 rpm by the message "Imbalanced load".
The run will terminate.
Check the loading and start the centrifuge once again. See the information on proper loading in the rotor instruction manual. For information on troubleshooting, see section “Troubleshooting by User” on page 7-3.
Stopping the centrifugation program
With preset running time
Usually the running time is preset and you only have to wait until the centrifuge stops automatically when the preset time limit expires.
4 OperationTemperature Adaptation during Standstill
Thermo Scientific Sorvall Legend XT 4-11
As soon as the speed drops to zero, the message END will appear in the display. By pressing the OPEN key , you can open the lid and remove the centrifuge material.
You can also stop the centrifuging program manually at any time by pressing the STOP key .
Continuous operation
If you selected continuous operation (see “Continuous operation” on page 4-6), you will have to stop the centrifuge manually. Press the STOP key on the control panel. The centrifuge will be decelerated at the designated rate. The message "END" will illuminate, and after pressing the key OPEN , the lid will open and you can remove the centrifuged material.
Temperature Adaptation during StandstillThe temperature cannot be adapted until the rotor has been positively identified. For this, the centrifuge must have accelerated to over 500 rpm. The speed display will then show END.
When the rotor is not recognized (lid closed and START key not yet pressed, speed display "0"), the centrifuge responds by ensuring that the sample cannot freeze regardless of the rotor being used.
Short-term CentrifugationFor short-term centrifuging, the Sorvall Legend XT/XTR has a PULSE- function.
By holding down the PULSE key , spinning will start and continue until the key is let go.
The centrifuge accelerates and brakes at maximum power. Any rpm or RCF entered beforehand is overridden.
Check carefully whether you have to maintain a certain speed for your application.
During the acceleration process, time is counted forwards in seconds. The reading stays displayed until the centrifuge lid is opened.
Removing the RotorTo remove the rotor, proceed as follows:
1. Open the centrifuge lid.
2. Grab the rotor handle with both hands and press against the green AutoLockTM key. At the same time, pull the rotor directly upwards with both hands and remove it from the centrifuge spindle. Make sure not to tilt the rotor while doing this.
Note The centrifuge accelerates to maximum speed, regardless of which rotor was installed.
4 OperationAerosol-tight Rotors
4-12 Sorvall Legend XT Thermo Scientific
Figure 4-2. Pressing AutoLockTM key
Aerosol-tight RotorsWhen using an aerosol tight lid the rotor can only be removed with the lid closed. This is to protect you and the samples.
Figure 4-3. AutoLockTM-lid for aerosol-tight rotors
Aligning the Centrifuge1. To turn off the centrifuge put the mains switch to "0".
CAUTION Rotors supplied with a lid for aerosol-tight applications come with a mandrill, which belongs to the AutoLockTM . Be sure not to place the lid onto this mandrill to prevent it from being damaged.
WARNING Mind the AutoLockTM-mandrill inside the lid. Do not touch the mandrill.
Thermo Scientific Sorvall Legend XT 5-1
5
System MenuEnter system menu?
End of run beep? No
Keypad beep? No
No
No ____Lid passcode?
Language 1.. 7: English1 English
2 Deutsch
3 Française
4 Español
5 Italiano
6 Nederlands
7 Росский
STOP
ENTER
LCD powersave?
START
0 no
1 yes
ENTER
ENTER
NoProgram passcodes?
0 0547V011
1 Software and NVRAMidentification example display
1 4641V05
ENTER STOP
ENTERSet lid passcode
ENTER
NoAuto lid open?
ENTER
ENTER
0547V01Software ID:
2368Cycle count:
ENTER
5 System MenuDescription
5-2 Sorvall Legend XT Thermo Scientific
Description
Enter system menu
To enter the system menu hold down any of the keys when switching the centrifuge on.
Press the ENTER key in order to navigate through the system menu.
Press the STOP key to quit the system menu.
Language
In order to change the language in the display, press the number next to the desired language in the diagram on the numeric pad.
Press ENTER key to confirm.
End of run beep
Press 1 (yes) on the numeric pad if the centrifuge should make beep after the run. Otherwise press 0 (no).
Press ENTER key to confirm.
Keypad beep
Press 1 (yes) on the numeric pad if the centrifuge should make beep when pressing any key. Otherwise press 0 (no).
Press ENTER key to confirm.
LCD powersave
Press 1 (yes) on the numeric pad if the centrifuge should enter a powdersave mode after the run. Otherwise press 0 (no).
Press ENTER key to confirm.
Lid passcode
Press 1 (yes) on the numeric pad if the centrifuge door should be protected with a passcode. Enter passcode.
If the door should not be protected with a passcode press 2 (no) on the numeric pad.
Press ENTER key to confirm.
Program passcodes
Press 1 (yes) on the numeric pad if the centrifuge programs should be protected with a passcode. Otherwise press 0 (no).
Press ENTER key to confirm.
5 System MenuDescription
Thermo Scientific Sorvall Legend XT 5-3
Auto lid open
Press 1 (yes) on the numeric pad if the centrifuge should open after the run. Otherwise press 0 (no).
Press ENTER key to confirm.
Software ID
Here you fine the current software version.
Press ENTER key to confirm.
Cycle count
Here you fine the current numbers of cycles.
Press ENTER key to confirm.
Thermo Scientific Sorvall Legend XT 6-1
6
Maintenance and Care
Contents
• “Cleaning Intervalls” on page 6-2
• “Cleaning” on page 6-2
• “Disinfection” on page 6-3
• “Decontamination” on page 6-4
• “Autoclaving” on page 6-5
• “Service of Thermo Fisher Scientific” on page 6-5
6 Maintenance and CareCleaning Intervalls
6-2 Sorvall Legend XT Thermo Scientific
Cleaning IntervallsFor the sake of personal, environmental, and material protection, it is your duty to clean and if necessary disinfect the centrifuge on a regular basis.
CleaningWhen cleaning centrifug
• Use warm water with a neutral solvent.
• Never use caustic cleaning agents such as soap suds, phosphoric acid, bleaching solutions or scrubbing powder.
• Rinse the cavities out thoroughly.
• Use a soft brush without metal bristles to remove stubborn residue.
• Afterwards rinse with distilled water.
• Place the rotors on a plastic grate with their cavities pointing down.
• If drying boxes are used, the temperature must never exceed 50 °C, since higher temperatures could damage the material and shorten the lifetime of the parts.
• Use only disinfectants with a pH of 6-8.
• Dry aluminum parts off with a soft cloth.
• After cleaning, treat the entire surface of aluminum parts with corrosion protection oil (7000 9824). Also treat the cavities with oil.
• Store the aluminum parts at room temperature or in a cold-storage room with the cavities pointing down.
Maintenance Recommended interval
Clean rotor chamber daily or when polluted
Clean rotor daily or when polluted
Accessories daily or when polluted
Cabinet Once per month
Ventilation holes Every six months
CAUTION Refrain from using any other cleaning or decontamination procedure than those recommended here, if you are not entirely sure that the intended procedure is safe for the equipment.Use only approved cleansers.If in doubt, contact Thermo Fisher Scientific.
6 Maintenance and CareDisinfection
Thermo Scientific Sorvall Legend XT 6-3
Clean centrifuge and accessories as follows:
1. Open the centrifuge.
2. Turn off the centrifuge.
3. Pull out the power supply plug.
4. Grasp the rotor with both hands and lift it vertically off the centrifuge spindle.
5. Remove the centrifuge tubes and adaptors.
6. Use a neutral cleaning agent with a pH value between 6 and 8 for cleaning.
7. Dry all of the rotors and accessorie after cleaning with a cloth or in a warm air cabinet at amaximum temperature of 50°C.
• After cleaning, treat the entire surface of aluminum parts with corrosion protection oil (70009824). Also treat the cavities with oil.
• Tread the bold of the swing out rotor with bold grease (75003786).
After some applications their might be ice in the rotor chamber. Let the ice melt and drain it off. Clean the rotor chamber as described above.
DisinfectionDisinfect the centrifuge immediately whenever infectious material has spilled during centrifugation.
The rotor chamber and the rotor should be treated preferably with a neutral disinfectant.
CAUTION Before using any cleaning or decontamination methods except those recommended by the manufacturer, users should check with the manufacturer that the proposed method will not damage the equipment.
CAUTION When cleaning, do not allow liquids, especially organic solvents, to get on the drive shaft or the bearings of the centrifuge.Organic solvents break down the grease in the motor bearing. The drive shaft could freeze up.
WARNING Infectious material can get into the centrifuge when a tube breaks or as a result of spills. Keep in mind the risk of infection when touching the rotor and take all necessary precautions.In case of contamination, make sure that others are not put at risk.Decontaminate the affected parts immediately.Take other precautions if need be.
CAUTION Before using any cleaning or decontamination methods except those recommended by the manufacturer, users should check with the manufacturer that the proposed method will not damage the equipment.Observe the safety precautions and handling instructions for the cleaning agents used.
6 Maintenance and CareDecontamination
6-4 Sorvall Legend XT Thermo Scientific
Contact the Service Department of Thermo Fisher Scientific for questions regarding the use of other disinfectants.
Disinfect the rotor and accessories as follows:
1. Open the centrifuge.
2. Turn off the centrifuge.
3. Pull out the power supply plug.
4. Grasp the rotor with both hands and lift it vertically off the centrifuge spindle.
5. Remove the centrifuge tubes and adaptors and dispose of them or disinfect them.
6. Treat the rotor and accessories according to the instructions for the disinfectant. Adhere strictly to the given application times.
7. Be sure the disinfectant can drain off the rotor.
8. Rinse the rotor and accessories thoroughly with water.
9. Dispose of the disinfectant according to the applicable guidelines.
10. Dry all of the rotors and accessorie after cleaning with a cloth or in a warm air cabinet at a maximum temperature of 50°C.
• After cleaning, treat the entire surface of aluminum parts with corrosion protection oil (7000 9824). Also treat the cavities with oil.
• Tread the bold of the swing out rotor with bold grease (75003786).
DecontaminationDecantaminate the centrifuge immediately whenever radioactive material has spilled during centrifugation.
For general radioactive decontamination use a solution of equal parts of 70% ethanol, 10% SDS and water.
1. Open the centrifuge.
2. Turn off the centrifuge.
3. Pull out the power supply plug.
4. Grasp the rotor with both hands and lift it vertically off the centrifuge spindle.
WARNING Radioactive material can get into the centrifuge when a tube breaks or as a result of spills. Keep in mind the risk of infection when touching the rotor and take all necessary precautions.In case of contamination, make sure that others are not put at risk.Decontaminate the affected parts immediately.Take other precautions if need be.
CAUTION Before using any cleaning or decontamination methods except those recommended by the manufacturer, users should check with the manufacturer that the proposed method will not damage the equipment.
6 Maintenance and CareAutoclaving
Thermo Scientific Sorvall Legend XT 6-5
5. Remove the centrifuge tubes and adaptors and dispose of them or disinfect them.
6. Rinse the rotor first with ethanol and then with de-ionized water.
• Adhere strictly to the given application times.
7. Be sure the decontamination solution can drain off the rotor.
8. Rinse the rotor and accessories thoroughly with water.
9. Dispose of the decontamination solution according to the applicable guidelines.
10. Dry all of the rotors and accessorie after cleaning with a cloth or in a warm air cabinet at a maximum temperature of 50°C.
• After cleaning, treat the entire surface of aluminum parts with corrosion protection oil (7000 9824). Also treat the cavities with oil.
• Tread the bold of the swing out rotor with bold grease (75003786).
Autoclaving1. Before autoclaving clean rotor and accessories and described above.
2. Place the rotor on a flat surface.
• Rotors and adapter can beautoclaved at 121 °C.
• The maximum permissible autoclave cycle is 20 minutes at 121 °C.
Service of Thermo Fisher ScientificThermo Fisher Scientific recommends having the centrifuge and accessories serviced once a year by an authorized service technician. The service technicians check the following:
• the electrical equipment
• the suitability of the set-up site
• the lid lock and the safety system
• the rotor
• the fixation of the rotor and the drive shaft
Thermo Fisher Scientific offers inspection and service contracts for this work. Any necessary repairs are performed for free during the warranty period and afterwards for a charge. This is only valid if the centrifuge has only been mainained by a Thermo Fisher Scientific service technician.
Note No chemical additives are permitted in the steam.
CAUTION Never exceed the permitted temperature and duration when autoclaving.If the rotor shows signs of corrosion or wear, it must be replaced.
Thermo Scientific Sorvall Legend XT 7-1
7
Trouble Shooting
Contents
• “Mechanical Emergency Door Release” on page 7-2
• “Troubleshooting by User” on page 7-3
• “When to contact Customer Service” on page 7-5
7 Trouble ShootingMechanical Emergency Door Release
7-2 Sorvall Legend XT Thermo Scientific
Mechanical Emergency Door ReleaseDuring a power failure, you will not be able to open the centrifuge lid with the regular electric lid release. A mechanical override is provided to allow sample recovery in the case of an emergency. However, this should be used only in emergencies and after the rotor has come to a complete stop.
Always wait a few minutes until the rotor has come to a stop without braking. The brake does not work when there is no current. The braking process lasts much longer than usual.
Proceed as follows:
1. Make sure the rotor has stopped (view port in the lid).
2. Pull out the power supply plug.
3. On the back of the housing are two black plastic plugs which you can pry out of the back plate with a screwdriver or a knife. Pull the release cord attached to it at the same time to trigger the mechanical lid release. The lid will open and the samples can be removed.
Figure 7-1. Emergency Door Release
4. Push the cord back into the centrifuge and mount the plug.
WARNING The rotor can still be spinning at high speed. If touched, it can cause serious injuries.
WARNING Never use your hand or other tools to brake the rotor.
Note You need to pull both levers in order to unlock both locks.
Emergency Door Release
7 Trouble ShootingTroubleshooting by User
Thermo Scientific Sorvall Legend XT 7-3
5. Reconnect the centrifuge once the power has been restored. Switch on the centrifuge. Press the OPEN key to have the door locks operative again.
Troubleshooting by User
WARNING If you pull only one lever or you do not pressed the OPEN key to have the door locks operative again, the door might open while the rotor os still spinning.
If problems occur other than those listed in this table, the authorized customer service representative must be contacted.
Failure message Problem with centrifuge Possible causes and cures
Overtemperature The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Overheating in chamber.Check the function of the refrigeration unit. Clean the air inlet for the condenser.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Incorrect bucket ID The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Bucket code is undefined for the rotor detected, check the set points for the given bucket code. Is it permitted to use the current bucket in the rotor currently mounted?
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Unapproved rotor The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Rotor code is not in the rotor table.Is it permitted to use the rotor currently mounted in this device?
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Rotor ID failure The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
The rotor could not be identified.
Check to see if the rotor is properly installed.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Lid blocked Centrifuge does not open Restart the centrifuge.
The emergency lid release enables you to retrieve your samples.
If an error message appears again, inform Customer Service.
Motor overtemp. The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
7 Trouble ShootingTroubleshooting by User
7-4 Sorvall Legend XT Thermo Scientific
PCB overtemp. The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Emergency release The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
The lid opens while the device is running.
Close the lid and restart the centrifuge.
If an error message appears again, inform Customer Service.
Imbalanced load The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Imbalance detected.
Check the load placed in the rotor.
Check that the rotor cross bolts are well greased.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Check Set Speed The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
The set point speed is higher than the maximum rotor speed.
Correct the value.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-01 - E-12 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Error during the self-test of the centrifuge program and the electronics.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-13 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
The check sum in the data memory is incorrect.The software corrects errors automatically. Check the values of the set point settings, etc.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-15-E-16 Temperature sensor broken / controller defective
Malfunction in the temperature detection.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-17 Speed for rotor detection exceeded Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-21-E-22 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
The rotor could not be identified.
Check to see if the rotor is properly installed.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-23 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
The speed control measurement returned a different result.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-25-E-27 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Time has expired for the lid lock drive while opening the lid.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Failure message Problem with centrifuge Possible causes and cures
7 Trouble ShootingWhen to contact Customer Service
Thermo Scientific Sorvall Legend XT 7-5
When to contact Customer ServiceIf you need to contact customer service, please provide the order no. and the serial no. of your device. This information can be found on the back near the inlet for the power supply cable.
To identify the software version, proceed as follows:
1. Hold down any of the keys and then switch on the centrifuge. You enter the system menu.
2. Press the START key .
E-28 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Error during the self-test of the centrifuge program and the electronics.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-29 The centrifuge cannot be operated.
The run does not start.
Check wether you selected the right bucket.Is it easy to turn the rotor when the lid is open? Does the rotor rub against the device?
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-30 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-33 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Overpressure in the refrigeration unit.
Clean the air inlet for the condenser.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-34-E-36 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Error during the self-test of the centrifuge program and the electronics.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-40 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
The centrifuge accelerates too slowly.
Is the rotor properly installed?Check wether you selected the right bucket. Is it easy to turn the rotor when the lid is open? Does the rotor rub against the device?
Restart the centrifuge.
If an error message appears again, inform Customer Service.
E-41-E-74 The centrifuge cannot be operated.
The run does not start or the centrifuge runs down without being braked.
Error during the self-test of the centrifuge program and the electronics.
Restart the centrifuge.
If an error message appears again, inform Customer Service.
Failure message Problem with centrifuge Possible causes and cures
7 Trouble ShootingWhen to contact Customer Service
7-6 Sorvall Legend XT Thermo Scientific
3. Press and hold the ENTER key , until the following message is displayed:
4. Communicate the software version to the service technician.
Software ID: XXXXXXXX
Thermo Scientific Sorvall Legend XT A-1
A
Chemical Compatibility Chart
CHEMICAL
MAT
ERIA
LAL
UMIN
UM
ANOD
IC C
OATI
NG
for A
LUM
INUM
BUN
A N
CELL
ULOS
E AC
ETAT
E BU
TYRA
TE
POLY
URET
HAN
E RO
TOR
PAIN
T
COM
POSI
TE C
arbo
n Fi
ber/
Epox
y
DELR
IN®
ETHY
LEN
E PR
OPYL
ENE
GLAS
S
NEO
PREN
E
NOR
YL®
NYL
ON
PET1 , P
OLYC
LEAR
®,C
LEAR
CRIM
P®CC
CLEA
RCRI
MP®
POLY
ALLO
MER
POLY
CARB
ONAT
E
POLY
ESTE
R, G
LASS
THE
RMOS
ET
POLY
THER
MID
E
POLY
RTHY
LEN
E
POLY
PROP
YLEN
E
POLY
SULF
ONE
POLY
VIN
YL C
HLOR
IDE
RULO
N A
®, T
EFLO
N®
SILI
CON
E RU
BBER
STAI
NLE
SS S
TEEL
TITA
NIU
M
TYGO
N®
VITO
N®
2-mercaptoethanol S S U - S M S - S U S S U S S - S S S S U S S S S S S
Acetaldehyde S - U U - - - M - U - - - M U U U M M - M S U - S - U
Acetone M S U U S U M S S U U S U S U U U S S U U S M M S U U
Acetonitrile S S U - S M S - S S U S U M U U - S M U U S S S S U U
Alconox® U U S - S S S - S S S S S S M S S S S S S S S S S S U
Allyl Alcohol - - - U - - S - - - - S - S S M S S S - M S - - S - -
Aluminum Chloride U U S S S S U S S S S M S S S S - S S S S S M U U S S
Formic Acid (100%) - S M U - - U - - - - U - S M U U S S - U S - U S - U
Ammonium Acetate S S U - S S S - S S S S S S S U - S S S S S S S S S S
Ammonium Carbonate M S U S S S S S S S S S S S U U - S S S S S S M S S S
Ammonium Hydroxide (10%) U U S U S S M S S S S S - S U M S S S S S S S S S M S
Ammonium Hydroxide (28%) U U S U S U M S S S S S U S U M S S S S S S S S S M S
Ammonium Hydroxide (conc.) U U U U S U M S - S - S U S U U S S S - M S S S S - U
Ammonium Phosphate U - S - S S S S S S S S - S S M - S S S S S S M S S S
Ammonium Sulfate U M S - S S U S S S S S S S S S - S S S S S S U S S U
Amyl Alcohol S - M U - - S S - M - S - M S S S S M - - - U - S - M
Aniline S S U U S U S M S U U U U U U U - S M U U S S S S U S
Sodium Hydroxide (<1%) U - M S S S - - S M S S - S M M S S S S S S M S S - U
Sodium Hydroxide (10%) U - M U - - U - M M S S U S U U S S S S S S M S S - U
Barium Salts M U S - S S S S S S S S S S S M - S S S S S S M S S S
Benzene S S U U S U M U S U U S U U U M U M U U U S U U S U S
A Chemical Compatibility Chart
A-2 Sorvall Legend XT Thermo Scientific
Benzyl Alcohol S - U U - - M M - M - S U U U U U U U - M S M - S - S
Boric Acid U S S M S S U S S S S S S S S S U S S S S S S S S S S
Cesium Acetate M - S - S S S - S S S S - S S - - S S S S S S M S S S
Cesium Bromide M S S - S S S - S S S S S S S - - S S S S S S M S S S
Cesium Chloride M S S U S S S - S S S S S S S - - S S S S S S M S S S
Cesium Formate M S S - S S S - S S S S S S S - - S S S S S S M S S S
Cesium Iodide M S S - S S S - S S S S S S S - - S S S S S S M S S S
Cesium Sulfate M S S - S S S - S S S S S S S - - S S S S S S M S S S
Chloroform U U U U S S M U S U U M U M U U U M M U U S U U U M S
Chromic Acid (10%) U - U U S U U - S S S U S S M U M S S U M S M U S S S
Chromic Acid (50%) U - U U - U U - - - S U U S M U M S S U M S - U M - S
Cresol Mixture S S U - - - S - S U U U U U U - - U U - U S S S S U S
Cyclohexane S S S - S S S U S U S S U U U M S M U M M S U M M U S
Deoxycholate S S S - S S S - S S S S S S S - - S S S S S S S S S S
Distilled Water S S S S S S S S S S S S S S S S S S S S S S S S S S S
Dextran M S S S S S S - S S S S S S S S S S S S S S S M S S S
Diethyl Ether S S U U S S S U S U U S U U U U U U U U U S S S S M U
Diethyl Ketone S - U U - - M - S U - S - M U U U M M - U S - - S U U
Diethylpyrocarbonate S S U - S S S - S S U S U S U - - S S S M S S S S S S
Dimethylsulfoxide S S U U S S S - S U S S U S U U - S S U U S S S S U U
Dioxane M S U U S S M M S U U S U M U U - M M M U S S S S U U
Ferric Chloride U U S - - - M S - M - S - S - - - S S - - - M U S - S
Acetic Acid (Glacial) S S U U S S U M S U S U U U U U M S U M U S U U S - U
Acetic Acid (5%) S S M S S S M S S S S S M S S S S S S S M S S M S S M
Acetic Acid (60%) S S U U S S U - S M S U U M U S M S M S M S M U S M U
Ethyl Acetate M M U U S S M M S S U S U M U U - S S U U S M M S U U
Ethyl Alcohol (50%) S S S S S S M S S S S S U S U S S S S S S S S M S M U
Ethyl Alcohol (95%) S S S U S S M S S S S S U S U - S S S M S S S U S M U
Ethylene Dichloride S - U U - - S M - U U S U U U U U U U - U S U - S - S
CHEMICAL
MAT
ERIA
LAL
UMIN
UM
ANOD
IC C
OATI
NG
for A
LUM
INUM
BUN
A N
CELL
ULOS
E AC
ETAT
E BU
TYRA
TE
POLY
URET
HAN
E RO
TOR
PAIN
T
COM
POSI
TE C
arbo
n Fi
ber/
Epox
y
DELR
IN®
ETHY
LEN
E PR
OPYL
ENE
GLAS
S
NEO
PREN
E
NOR
YL®
NYL
ON
PET1 , P
OLYC
LEAR
®,C
LEAR
CRIM
P®CC
CLEA
RCRI
MP®
POLY
ALLO
MER
POLY
CARB
ONAT
E
POLY
ESTE
R, G
LASS
THE
RMOS
ET
POLY
THER
MID
E
POLY
RTHY
LEN
E
POLY
PROP
YLEN
E
POLY
SULF
ONE
POLY
VIN
YL C
HLOR
IDE
RULO
N A
®, T
EFLO
N®
SILI
CON
E RU
BBER
STAI
NLE
SS S
TEEL
TITA
NIU
M
TYGO
N®
VITO
N®
A Chemical Compatibility Chart
Thermo Scientific Sorvall Legend XT A-3
Ethylene Glycol S S S S S S S S S S S S - S U S S S S S S S S M S M S
Ethylene Oxide Vapor S - U - - U - - S U - S - S M - - S S S U S U S S S U
Ficoll-Hypaque® M S S - S S S - S S S S - S S - S S S S S S S M S S S
Hydrofluoric Acid (10%) U U U M - - U - - U U S - S M U S S S S M S U U U - -
Hydrofluoric Acid (50%) U U U U - - U - - U U U U S U U U S S M M S U U U - M
Hydrochloric Acid (conc.) U U U U - U U M - U M U U M U U U - S - U S U U U - -
Formaldehyde (40%) M M M S S S S M S S S S M S S S U S S M S S S M S M U
Glutaraldehyde S S S S - - S - S S S S S S S - - S S S - - S S S - -
Glycerol M S S - S S S S S S S S S S S S - S S S S S S S S S S
Guanidine Hydrochloride U U S - S S S - S S S S S S S - - S S S S S S U S S S
Haemo-Sol® S S S - - - S - S S S S S S S - - S S S S S S S S S S
Hexane S S S - S S S - S S U S U M U S S U S S M S U S S U S
Isobutyl Alcohol - - M U - - S S - U - S U S S M S S S - S S S - S - S
Isopropyl Alcohol M M M U S S S S S U S S U S U M S S S S S S S M M M S
Iodoacetic Acid S S M - S S S - S M S S M S S - M S S S S S M S S M M
Potassium Bromide U S S - S S S - S S S S S S S S S S S - S S S M S S S
Potassium Carbonate M U S S S S S - S S S S S S U S S S S S S S S S S S S
Potassium Chloride U S S - S S S S S S S S S S S - S S S S S S S U S S S
Potassium Hydroxide (5%) U U S S S S M - S S S S - S U S S S S S S S M U M S U
Potassium Hydroxide (conc.) U U M U - - M - M S S - U M U U U S M - M U - U U - U
Potassium Permanganate S S S - S S S - S S S U S S S M - S M S U S S M S U S
Calcium Chloride M U S S S S S S S S S S S S M S - S S S S S S M S S S
Calcium Hypochlorite M - U - S M M S - M - S - S M S - S S S M S M U S - S
Kerosene S S S - S S S U S M U S U M M S - M M M S S U S S U S
Sodium Chloride (10%) S - S S S S S S - - - S S S S S - S S S S - S S M - S
Sodium Chloride (sat'd) U - S U S S S - - - - S S S S S - S S - S - S S M - S
Carbon Tetrachloride U U M S S U M U S U U S U M U S S M M S M M M M U S S
Aqua Regia U - U U - - U - - - - - U U U U U U U - - - - - S - M
Solution 555 (20%) S S S - - - S - S S S S S S S - - S S S - S S S S S S
CHEMICAL
MAT
ERIA
LAL
UMIN
UM
ANOD
IC C
OATI
NG
for A
LUM
INUM
BUN
A N
CELL
ULOS
E AC
ETAT
E BU
TYRA
TE
POLY
URET
HAN
E RO
TOR
PAIN
T
COM
POSI
TE C
arbo
n Fi
ber/
Epox
y
DELR
IN®
ETHY
LEN
E PR
OPYL
ENE
GLAS
S
NEO
PREN
E
NOR
YL®
NYL
ON
PET1 , P
OLYC
LEAR
®,C
LEAR
CRIM
P®CC
CLEA
RCRI
MP®
POLY
ALLO
MER
POLY
CARB
ONAT
E
POLY
ESTE
R, G
LASS
THE
RMOS
ET
POLY
THER
MID
E
POLY
RTHY
LEN
E
POLY
PROP
YLEN
E
POLY
SULF
ONE
POLY
VIN
YL C
HLOR
IDE
RULO
N A
®, T
EFLO
N®
SILI
CON
E RU
BBER
STAI
NLE
SS S
TEEL
TITA
NIU
M
TYGO
N®
VITO
N®
A Chemical Compatibility Chart
A-4 Sorvall Legend XT Thermo Scientific
Magnesium Chloride M S S - S S S S S S S S S S S S S S S S S S S M S S S
Mercaptoacetic Acid U S U - S M S - S M S U U U U - S U U S M S U S S S S
Methyl Alcohol S S S U S S M S S S S S U S U M S S S S S S S M S M U
Methylene Chloride U U U U M S S U S U U S U U U U U M U U U S S M U S U
Methyl Ethyl Ketone S S U U S S M S S U U S U S U U U S S U U S S S S U U
Metrizamide® M S S - S S S - S S S S - S S - - S S S S S S M S S S
Lactic Acid (100%) - - S - - - - - - M S U - S S S M S S - M S M S S - S
Lactic Acid (20%) - - S S - - - - - M S M - S S S S S S S M S M S S - S
N-Butyl Alcohol S - S U - - S - - S M - U S M S S S S M M S M - S - S
N-Butyl Phthalate S S U - S S S - S U U S U U U M - U U S U S M M S U S
N, N-Dimethylformamide S S S U S M S - S S U S U S U U - S S U U S M S S S U
Sodium Borate M S S S S S S S S S S U S S S S - S S S S S S M S S S
Sodium Bromide U S S - S S S - S S S S S S S S - S S S S S S M S S S
Sodium Carbonate (2%) M U S S S S S S S S S S S S U S S S S S S S S S S S S
Sodium Dodecyl Sulfate S S S - S S S - S S S S S S S - S S S S S S S S S S S
Sodium Hypochlorite (5%) U U M S S M U S S M S S S M S S S S M S S S M U S M S
Sodium Iodide M S S - S S S - S S S S S S S - - S S S S S S M S S S
Sodium Nitrate S S S - S S S S S S S S S S S S - S S S S S U S S S S
Sodium Sulfate U S S - S S S S S S S S S S S S S S S S S S S M S S S
Sodium Sulfide S - S S - - - S - - - S S S U U - - S - - - S S M - S
Sodium Sulfite S S S - S S S S M S S S S S S M - S S S S S S S S S S
Nickel Salts U S S S S S - S S S - - S S S S - S S S S S S M S S S
Oils (Petroleum) S S S - - - S U S S S S U U M S M U U S S S U S S S S
Oils (Other) S - S - - - S M S S S S U S S S S U S S S S - S S M S
Oleic Acid S - U S S S U U S U S S M S S S S S S S S S M U S M M
Oxalic Acid U U M S S S U S S S S S U S U S S S S S S S S U M S S
Perchloric Acid (10%) U - U - S U U - S M M - - M U M S M M - M S U - S - S
Perchloric Acid (70%) U U U - - U U - S U M U U M U U U M M U M S U U S U S
Phenol (5%) U S U - S M M - S U M U U S U M S M S U U S U M M M S
CHEMICAL
MAT
ERIA
LAL
UMIN
UM
ANOD
IC C
OATI
NG
for A
LUM
INUM
BUN
A N
CELL
ULOS
E AC
ETAT
E BU
TYRA
TE
POLY
URET
HAN
E RO
TOR
PAIN
T
COM
POSI
TE C
arbo
n Fi
ber/
Epox
y
DELR
IN®
ETHY
LEN
E PR
OPYL
ENE
GLAS
S
NEO
PREN
E
NOR
YL®
NYL
ON
PET1 , P
OLYC
LEAR
®,C
LEAR
CRIM
P®CC
CLEA
RCRI
MP®
POLY
ALLO
MER
POLY
CARB
ONAT
E
POLY
ESTE
R, G
LASS
THE
RMOS
ET
POLY
THER
MID
E
POLY
RTHY
LEN
E
POLY
PROP
YLEN
E
POLY
SULF
ONE
POLY
VIN
YL C
HLOR
IDE
RULO
N A
®, T
EFLO
N®
SILI
CON
E RU
BBER
STAI
NLE
SS S
TEEL
TITA
NIU
M
TYGO
N®
VITO
N®
A Chemical Compatibility Chart
Thermo Scientific Sorvall Legend XT A-5
Phenol (50%) U S U - S U M - S U M U U U U U S U M U U S U U U M S
Phosphoric Acid (10%) U U M S S S U S S S S U - S S S S S S S S S U M U S S
Phosphoric Acid (conc.) U U M M - - U S - M S U U M M S S S M S M S U M U - S
Physiologic Media (Serum, Urine) M S S S - - S - S S S S S S S S S S S S S S S S S S S
Picric Acid S S U - S M S S S M S U S S S U S S S S U S U M S M S
Pyridine (50%) U S U U S U U - U S S U U M U U - U S M U S S U U U U
Rubidium Bromide M S S - S S S - S S S S S S S - - S S S S S S M S S S
Rubidium Chloride M S S - S S S - S S S S S S S - - S S S S S S M S S S
Sucrose M S S - S S S S S S S S S S S S S S S S S S S S S S S
Sucrose, Alkaline M S S - S S S - S S S S S S U S S S S S S S S M S S S
Sulfosalicylic Acid U U S S S S S - S S S U S S S - S S S - S S S U S S S
Nitric Acid (10%) U S U S S U U - S U S U - S S S S S S S S S M S S S S
Nitric Acid (50%) U S U M S U U - S U S U U M M U M M M S S S U S S M S
Nitric Acid (95%) U - U U - U U - - U U U U M U U U U M U U S U S S - S
Hydrochloric Acid (10%) U U M S S S U - S S S U U S U S S S S S S S S U M S S
Hydrochloric Acid (50%) U U U U S U U - S M S U U M U U S S S S M S M U U M M
Sulfuric Acid (10%) M U U S S U U - S S M U S S S S S S S S S S U U U S S
Sulfuric Acid (50%) M U U U S U U - S S M U U S U U M S S S S S U U U M S
Sulfuric Acid (conc.) M U U U - U U M - - M U U S U U U M S U M S U U U - S
Stearic Acid S - S - - - S M S S S S - S S S S S S S S S M M S S S
Tetrahydrofuran S S U U S U U M S U U S U U U - M U U U U S U S S U U
Toluene S S U U S S M U S U U S U U U S U M U U U S U S U U M
Trichloroacetic Acid U U U - S S U M S U S U U S M - M S S U U S U U U M U
Trichloroethane S - U - - - M U - U - S U U U U U U U U U S U - S - S
Trichloroethylene - - U U - - - U - U - S U U U U U U U U U S U - U - S
Trisodium Phosphate - - - S - - M - - - - - - S - - S S S - - S - - S - S
Tris Buffer (neutral pH) U S S S S S S - S S S S S S S S S S S S S S S S S S S
Triton X-100® S S S - S S S - S S S S S S S S S S S S S S S S S S S
Urea S - U S S S S - - - - S S S M S S S S - S S S M S - S
CHEMICAL
MAT
ERIA
LAL
UMIN
UM
ANOD
IC C
OATI
NG
for A
LUM
INUM
BUN
A N
CELL
ULOS
E AC
ETAT
E BU
TYRA
TE
POLY
URET
HAN
E RO
TOR
PAIN
T
COM
POSI
TE C
arbo
n Fi
ber/
Epox
y
DELR
IN®
ETHY
LEN
E PR
OPYL
ENE
GLAS
S
NEO
PREN
E
NOR
YL®
NYL
ON
PET1 , P
OLYC
LEAR
®,C
LEAR
CRIM
P®CC
CLEA
RCRI
MP®
POLY
ALLO
MER
POLY
CARB
ONAT
E
POLY
ESTE
R, G
LASS
THE
RMOS
ET
POLY
THER
MID
E
POLY
RTHY
LEN
E
POLY
PROP
YLEN
E
POLY
SULF
ONE
POLY
VIN
YL C
HLOR
IDE
RULO
N A
®, T
EFLO
N®
SILI
CON
E RU
BBER
STAI
NLE
SS S
TEEL
TITA
NIU
M
TYGO
N®
VITO
N®
A Chemical Compatibility Chart
A-6 Sorvall Legend XT Thermo Scientific
Chemical resistance data is included only as a guide to product use. No organized chemical resistance data exists for materials under the stress of centrifugation. When in doubt we recommend pretesting sample lots.
Hydrogen Peroxide (10%) U U M S S U U - S S S U S S S M U S S S S S S M S U S
Hydrogen Peroxide (3%) S M S S S - S - S S S S S S S S M S S S S S S S S S S
Xylene S S U S S S M U S U U U U U U M U M U U U S U M S U S
Zinc Chloride U U S S S S U S S S S S S S S S S S S S S S S U S S S
Zinc Sulfate U S S - S S S S S S S S S S S S S S S S S S S S S S S
Citric Acid (10%) M S S M S S M S S S S S S S S S M S S S S S S S S S S
1Polyethyleneterephthalate
CHEMICAL
MAT
ERIA
LAL
UMIN
UM
ANOD
IC C
OATI
NG
for A
LUM
INUM
BUN
A N
CELL
ULOS
E AC
ETAT
E BU
TYRA
TE
POLY
URET
HAN
E RO
TOR
PAIN
T
COM
POSI
TE C
arbo
n Fi
ber/
Epox
y
DELR
IN®
ETHY
LEN
E PR
OPYL
ENE
GLAS
S
NEO
PREN
E
NOR
YL®
NYL
ON
PET1 , P
OLYC
LEAR
®,C
LEAR
CRIM
P®CC
CLEA
RCRI
MP®
POLY
ALLO
MER
POLY
CARB
ONAT
E
POLY
ESTE
R, G
LASS
THE
RMOS
ET
POLY
THER
MID
E
POLY
RTHY
LEN
E
POLY
PROP
YLEN
E
POLY
SULF
ONE
POLY
VIN
YL C
HLOR
IDE
RULO
N A
®, T
EFLO
N®
SILI
CON
E RU
BBER
STAI
NLE
SS S
TEEL
TITA
NIU
M
TYGO
N®
VITO
N®
Key
S Satisfactory
M Moderate attack, may be satisfactory for use in centrifuge depending on length of exposure, speed involved, etc. Suggest testing under actual conditions of use.
U Unsatisfactory, not recommended.
-- Performance unknown; suggest testing, using sample to avoid loss of valuable material.
Thermo Scientific Sorvall Legend XT B-1
B
Contact Information
United States 866-9-THERMO
+1 866 984 3766
Canada +1 866 984 3766
Austria +43 1 801 400
Belgium +32 2 482 30 30
Germany 08001 536 376
+49 6184 90 6940
France +33 2 2803 2180
+33 2 2803 2000
Italy +39 02 02 95059 341
Netherlands +31 76 571 4440
Nordic / Baltic Countries +35 89 329 100
Russia +7 (812) 703 42 15
B Contact Information
B-2 Sorvall Legend XT Thermo Scientific
Spain +34 932 23 09 18
Portugal +34 932 23 09 18
Switzerland +41 44 454 12 12
UK / Ireland +44 870 609 9203
China +86 21 6865 4588
+86 10 8419 3588
India +91 22 6716 2200
Japan +81 45 453 9220
Other Asian Countries +852 2885 4613
Latin America +1 866 984 3766
Other Countries +49 6184 90 6940
+33 2 2803 2180
Other Countries +49 6184 90 6940
+33 2 2803 2180
Thermo Scientific Sorvall Legend XT I-1
I
AAcceleration curve ...........................................4-4Accident Prevention .......................................... ivAerosol-tight Rotors ......................................4-12Aligning the Centrifuge ...................................2-3Autoclaving .....................................................6-5
BBraking curve ..................................................4-4Bucket radius ..................................................4-8Bucket selection ..............................................4-8
CCare ................................................................6-1Centrifugation ...............................................4-10Cleaning ..........................................................6-2Cleaning Intervalls ..........................................6-2Close Lid .........................................................4-2Continuous Operation ...........................4-6, 4-11Control Panel ..................................................3-2
DDecontamination ............................................6-4Disinfection ....................................................6-3
EEmergency Door Release .................................7-2Entering Parameters ........................................4-4Explanation of RCF Value ..............................4-5
FFailure message ...............................................7-3Features ...........................................................1-5
IImbalance indicator .......................................4-10Intended Use ...................................................... v
KKeys ................................................................3-2Kundendienst ...........................................6-5, 7-5
LLid Opening ....................................................4-2Location ..........................................................2-2
MMains Connection ...........................................2-3Mains Supply ...........................................1-5, 2-4Maintenance ...................................................6-1
OOperation ........................................................4-1Overwriting a passcode-protected program ......4-9Overwriting a program ....................................4-9
PPasscode ..........................................................4-9Precautions ........................................................ ivPreface ............................................................... iiiPreselecting RCF .............................................4-4Preselecting Speed ...........................................4-4Preselecting the temperature ............................4-6Preset Running Time ....................................4-10Prewarming or Precooling ...............................4-7Prewarming or precooling the centrifuge .........4-7
RRemoving the Rotor ......................................4-11Rotor Installation ............................................4-2Rotor Selection ................................................1-6Running time preselection ...............................4-5
SSafety features .................................................1-2
Index
Index:
I-2 Sorvall Legend XT Thermo Scientific
Safety zone ......................................................2-2Select Program ................................................4-9Short-term Centrifugation ............................4-11Starting centrifuge program ...........................4-10Stopping the centrifugation program .............4-10Storage ............................................................2-4Switch on Centrifuge ......................................4-2
TTechnical Data ................................................1-3Temperature Adaptation ...............................4-11Transporting the Centrifuge ............................2-2Trouble Shooting ............................................7-1